Location
9 Coromandel Approach, North Coogee

Description
Class 7a car parking at Ground, Level 1 and 2, and Class 2 SOUs (sole occupancy units/apartments) from Ground to Level 8

Fire Safety issues addressed
Unprotected openings within 3 m of the site boundary
Extended separation distance between exits within the residential component of the building
Building included more than 2 access points in a fire isolated passageway without the provision of compliant smoke lobbies

Performance Solutions
Increasing the number of horizontal exits provided from the car park at Levels 1 & 2
Repositioning the discharge location of a fire isolated exit
Omission of fire hose reels from the residential areas
Provision of a void between Ground and Level 2 within one of the main entry lobbies.